Heat pump sizing estimate (preliminary)

A preliminary heating and cooling planning figure for a home. Change the inputs and the factor table shows every multiplier behind the number. It is the same estimate the PORTREX showroom shows.

Planning aid only. Not a quote, not an engineering calculation.

Preliminary planning figure: about 54,000 BTU/h heating, 38,000 BTU/h cooling (about 3 tons)

This is a preliminary sizing estimate. It is not an ACCA Manual J load calculation. A qualified installer must perform the final sizing.

The figure uses the same simplified planning factors as the PORTREX in-home showroom. They are rules of thumb, not a standard. For what a real calculation requires, see the ACCA Manual J page.

Your home
Stories
Climate band

Each climate band comes with the winter and summer design temperatures the factors assume. Pick the band closest to your area.

Building shell
Insulation level
Window quality
Air sealing
Sun exposure
Heating / cooling, about54,000 / 38,000 BTU/hView sheet

Sizing sheet

Preliminary figure

8 ft1,800 sq ftColdWinter design 5°F · Summer design 87°F

Preliminary planning figure

Heating
about 54,000 BTU/h
Cooling
about 38,000 BTU/h
Size
about 3 tons

Preliminary. Not a Manual J calculation.

Every factor in the figure. Selected rows are marked.
FactorOptionHeatingCooling
Climate band: base BTU/h per sq ftHot-humid1630
Climate band: base BTU/h per sq ftWarm2026
Climate band: base BTU/h per sq ftMixed2523
Climate band: base BTU/h per sq ftCold (selected)3020
Climate band: base BTU/h per sq ftVery cold3818
Insulationpoorx 1.20x 1.20
Insulationaverage (selected)x 1.00x 1.00
Insulationgoodx 0.86x 0.86
Insulationexcellentx 0.74x 0.74
Windowssinglex 1.12x 1.15
Windowsdouble (selected)x 1.00x 1.00
Windowstriplex 0.90x 0.88
Air sealingleakyx 1.14x 1.08
Air sealingaverage (selected)x 1.00x 1.00
Air sealingtightx 0.88x 0.94
Sun exposureshadednot usedx 0.90
Sun exposuremixed (selected)not usedx 1.00
Sun exposuresunnynot usedx 1.12
Stories1x 1.04not used
Stories2 (selected)x 1.00not used
Stories3x 0.97not used
Ceiling heightheight in feet divided by 8 (selected)x height / 8x height / 8
Occupantsper person (selected)not used+ 600 BTU/h

Prices shown are preliminary. The contractor may adjust them for changes in costs related to materials, labor, fuel, permitting, regulations, site conditions, professional services, location, or transportation. Final pricing is confirmed after project evaluation and, where applicable, issuance of a Notice to Proceed (NTP).